Thomson currently has two account systems - one for the website and CAD model downloads, and one for e-commerce. We understand that two logins is an inconvenience and are working to consolidate our systems into one login process. Until we’re able to consolidate the two logins, please follow these guidelines:
The sensor is fixed in position by two M3 size locking screws (A1). The cable (A2) is molded into the sensor.
The magnetic sensor fits in to the T-slot running along three sides of the cover tube on an Electrak LA14, LA24 or FA14. On M50 Linear Units the magnetic sensors are mounted directly in the sensor slot of the profiles of the units and require no mounting bracket while Z2 and Z3 require magnetic sensor mounting brackets.
The cable is molded into the switch.
Maximum power 10 W, Maximum Volrage 43 Vdc, Maximum Current 0.5 A, Maximum Contact Resistance 0.2 Ohms, Cable Length 3000 mm
Lead Cross section 3 x 0.14 mm2
The normally closed sensors can be used with AC-063 controls that have limit switch inputs.
To provide better service to you on our websites, we and our service providers use cookies to collect your personal data when you browse. For information about our use of cookies and how to decline them or turn them off please read our cookie policy [available here].